Constant crosshead rate
Values from one curve
EN 10371 gets Fe from a bilinear fit (Figure 5), and Fi, Fm and um from the curve (Figure 7). The test ends when the force drops below 0.8 · Fm (7.2.5).

- Fe — elastic-plastic transition force (7.3.1)Fe = fABilinear fit O–A–B when you record u, with uB = h0. Trilinear fit when you record v. Always report the method.
- Fi — onset of plastic instability (7.3.3)Fi at uiFor the standard geometry and F(u), ui = 0.552 mm (Table C.1). Its position is almost independent of the tensile properties of the material.
- Fm, um — maximum force and its deflection (7.3.4, 7.3.5)Fm, umThe maximum force of the test and its deflection.
- ESP — small punch energy (7.3.6)ESP = ∫ F du, from 0 to umThe area below F(u) up to um.
If you record v in place of u, correct v for the compliance of the test rig (Annex A).